31
Thermostat: hand bend cap
tube end as shown
Thermostat and ice transport tube replacement
Ice transport tube: tube
may extend a maximum of
7mm (1/4") into ice bin
Top View
.25
ice tube
gasket
ice tube
retainer
13mm
(.50")
TYP
77mm
(3")
capillary
tube
bracket
Ice transport tube replacement
1. Push tube onto evaporator port.
2. Position clamp behind lip on evaporator port and tighten clamp.
51mm